Standard IOESTIV5200_270-600_SP6_SCT_Standard_Euro12_Euro67

IV5200_270-600_SP6_SCT_Standard_Euro12_Euro67

Source file: IV5200_270-600_SP6_SCT_Standard_Euro12_Euro67_20260501. Configuration: DI48 / DO64 / AI6 / AO8 + E502.

Main Board IO

Digital Input DI (48 points)

PointName
DI1Mechanical Safety Detection
DI2Safety Door 2 (NO)
DI3Core A Advance End
DI4Core A Retreat End
DI5Core B Advance End
DI6Core B Retreat End
DI7Mold Close End
DI8Mold Adjust Advance End
DI9Mold Adjust Retreat End
DI10
DI11Injection Guard
DI12Ejector Retreat End
DI13ROB Robot
DI14Carriage Advance End
DI15Rear Safety Door (Reverse Logic) (NC)
DI16Oil Filter Detection
DI17Screw Speed Detection
DI18Mold Adjust Photocell
DI19Detection Photocell 1
DI20Thread A Photocell
DI21Safety Door (Reverse Logic) (NC)
DI22~DI23
DI24Lubrication Detection
DI25~DI26
DI27Safety Door Anti-Collision (Electric Door Reserved)
DI28Safety Door Open (Electric Door Reserved)
DI29Electric Recovery Drive Fault
DI30~DI48

Digital Output DO (64 points)

PointName
DO1*Mold Close
DO2Recovery Linkage
DO3*Mold Open
DO4Injection
DO5Injection Retreat
DO6Recovery
DO7Carriage Advance
DO8Carriage Retreat
DO9Ejector Advance
DO10Ejector Retreat
DO11Core A Advance
DO12Core A Retreat
DO13Mold Adjust Advance
DO14Mold Adjust Retreat
DO15Core B Advance
DO16Core B Retreat
DO17IMM Safety Door
DO18Recovery Back Pressure
DO19Blow 1
DO20Recovery Zero Back Pressure
DO21
DO22Mold Open Fast
DO23Alarm
DO24Valve 1
DO25Mold Close Safety
DO26Auto Light
DO27Manual Light
DO28Blow 2
DO29Blow 6
DO30Blow 7
DO31Hopper Cooling (Reserved)
DO32Valve 2
DO33Heater 1
DO34Heater 2
DO35Heater 3
DO36Heater 4
DO37Heater 5
DO38Heater 6
DO39Heater 7
DO40Heater 8
DO41Heater 9
DO42Motor ON
DO43TC1 Heater ON (Master Heater ON)
DO44Lubrication
DO45IMM Robot
DO46Safety Door Close (Reserved)
DO47Safety Door Open (Reserved)
DO48Blow 8
DO49Eject Retreat Setting (Drip Tube Machine Only)
DO50Recovery Linkage
DO51Masterbatch Machine
DO52Lubrication Switch
DO53Oil Temp Cooling (Reserved)
DO54Blow 3
DO55Blow 4
DO56Blow 5
DO57Injection 2
DO58Valve 3 (Reserved)
DO59Valve 4 (Reserved)
DO60Recovery (Oil Motor Reserved)
DO61~DO64

Analog AI / AO

PointName
AI1Injection
AI2Mold Open/Close
AI3Ejector
AI4~AI6
AO1
AO2Electric Recovery
AO3Proportional Back Pressure
AO4Proportional Valve
AO5~AO8

Temperature TI (6-zone Input)

PointNote
TI0Oil Temp
TI1~TI9

IO Extension Board · Euro 67 Robot

Ext DISignalExt DOSignal
49 / E0165 / E01
50 / E0266 / E02
51 / E0367 / E03
52 / E0468 / E04
53 / E0569 / E05
54 / E0670 / E06
55 / E07ROB Allow Core 1 Advance71 / E07
56 / E08ROB Allow Core 1 Retreat72 / E08IMM Core 1 Advance Done
57 / E09ROB Allow Core 2 Advance73 / E09IMM Core 1 Retreat Done
58 / E10ROB Allow Core 2 Retreat74 / E10IMM Core 2 Advance Done
59 / E11ROB Allow Mold Close75 / E11IMM Core 2 Retreat Done
60 / E12ROB Robot E-Stop (Reverse Logic)76 / E12IMM Mold Open End
61 / E13ROB Mold Area Safety77 / E13IMM Eject Retreat Done
62 / E14ROB Robot Manual78 / E14IMM Eject Advance Done
63 / E15ROB Eject Retreat Safety79 / E15IMM Injection Auto
64 / E16ROB Eject Advance Safety80 / E16IMM Mold Close End

IO Extension Board · Euro 12 Robot

Ext DISignalExt DOSignal
49 / E0165 / E01
50 / E0266 / E02
51 / E0367 / E03
52 / E0468 / E04
53 / E0569 / E05
54 / E0670 / E06
55 / E0771 / E07
56 / E0872 / E08
57 / E0973 / E09
58 / E1074 / E10
59 / E11ROB Allow Mold Close75 / E11
60 / E12ROB Robot E-Stop (Reverse Logic)76 / E12IMM Mold Open End
61 / E13ROB Mold Area Safety77 / E13IMM Eject Retreat Done
62 / E14ROB Robot Manual78 / E14IMM Eject Advance Done
63 / E15ROB Eject Retreat Safety79 / E15IMM Injection Auto
64 / E16ROB Eject Advance Safety80 / E16IMM Mold Close End
  • E-Stop and Safety Doors use electrical wiring, not output points.
  • For Estun hosts, the IO extension board point layout is the same for Euro 12 / 67; actual electrical wiring differs.