5620_320-430_M8II(Techmation)_Proportional-Valve_Standard_Euro12_Euro67
Source file: 5620_320-430_M8II(Techmation)_Proportional-Valve_Standard_Euro12_Euro67_20260501. Configuration: DI32 / DO32 / TC 1+6 / AI4 / AO4V2A / RDO3+3. Euro 12 / Euro 67 robot have different extension points, see respective tables below.
Main Board IO
Digital Input DI (32 points)
| Point | Name |
|---|---|
| DI1 | Mechanical Safety Detection |
| DI2 | Safety Door 2 |
| DI3 | Core A Advance End |
| DI4 | Core A Retreat End |
| DI5 | Core B Advance End |
| DI6 | Core B Retreat End |
| DI7 | Mold Close End |
| DI8 | Mold Adjust Advance End |
| DI9 | Mold Adjust Retreat End |
| DI10 | — |
| DI11 | Injection Guard |
| DI12 | Eject Retreat End |
| DI13 | Robot -R |
| DI14 | Carriage Advance End |
| DI15 | Rear Safety Door Close End (Reverse Logic) |
| DI16 | Oil Filter Detection |
| DI17 | Recovery Speed |
| DI18 | Mold Adjust Photocell |
| DI19 | Detection Photocell |
| DI20 | Thread A Photocell |
| DI21 | Safety Door Close (Reverse Logic) |
| DI22 | Core C Advance End (Reserved) |
| DI23 | Core C Retreat End (Reserved) |
| DI24 | Lubrication Detection |
| DI25 | Hydraulic Oil Level Detection (430) |
| DI26 | — |
| DI27 | — |
| DI28 | — |
| DI29 | — |
| DI30 | Motor Phase Sequence Detection (430) |
| DI31 | External Control Pressure Insufficient (430) |
| DI32 | Cycle Start Button (430) |
Digital Output DO (32 points)
| Point | Name |
|---|---|
| DO1 | *Mold Close |
| DO2 | *Differential |
| DO3 | *Mold Open |
| DO4 | Injection |
| DO5 | Injection Retreat |
| DO6 | Recovery |
| DO7 | Carriage Advance |
| DO8 | Carriage Retreat |
| DO9 | Eject Advance |
| DO10 | Eject Retreat |
| DO11 | Core A Advance |
| DO12 | Core A Retreat |
| DO13 | Mold Adjust Advance |
| DO14 | Mold Adjust Retreat |
| DO15 | Core B Advance |
| DO16 | Core B Retreat |
| DO17 | Safety Door Close -R |
| DO18 | Recovery Back Pressure |
| DO19 | Blow 1 |
| DO20 | Zero Back Pressure |
| DO21 | — |
| DO22 | *Mold Open Slow Start (320) / Mold Open Fast (430) |
| DO23 | Alarm |
| DO24 | — |
| DO25 | Mold Close Safety Valve |
| DO26 | Auto Light |
| DO27 | Manual Light |
| DO28 | Blow 2 |
| DO29 | Core C Advance (Reserved) |
| DO30 | Core C Retreat (Reserved) |
| DO31 | Hopper Cooling (Reserved) |
| DO32 | Oil Temp Cooling (Reserved) / *Mold Close Low Pressure |
Fixed Extension DO (49~54)
| Point | Name |
|---|---|
| DO49 | Motor OFF |
| DO50 | Motor ON |
| DO51 | Y TO DELTA |
| DO52 | Heater ON |
| DO53 | Lubrication |
| DO54 | Robot -R |
Analog AI / AO
| Point | Name |
|---|---|
| AI1 | Injection |
| AI2 | Mold Open/Close |
| AI3 | Ejector |
| AI4 | — |
| AO1 | Pump 1 Pressure |
| AO2 | Pump 1 Flow |
| P3± | Proportional Back Pressure |
| P4± | — |
| AO5 | Proportional Valve |
| AO6 | Electric Recovery |
Temperature TI / TO
| Point | Note |
|---|---|
| TIOIL | Oil Temp |
| TI1 | — |
| TI2 | — |
| TI3 | — |
| TI4 | — |
| TI5 | — |
| TI6 | — |
| TO1 | — |
| TO2 | 90-170 (incl.) Models, 4 zones |
| TO3 | 218 Models, 5 zones |
| TO4 | 268-430 (incl.) Models, 6 zones |
| TO5 | — |
| TO6 | — |
Euro 12 Robot Extension Points
| Ext DI | Signal | Ext DO | Signal |
|---|---|---|---|
| 1 (DI57) | — | 1 (DO57) | — |
| 2 (DI58) | — | 2 (DO58) | — |
| 3 (DI59) | Mold Close Safety -R | 3 (DO59) | — |
| 4 (DI60) | Robot E-Stop -R | 4 (DO60) | Mold Open End -R |
| 5 (DI61) | Mold Area Safety -R | 5 (DO61) | Robot Eject Retreat -R |
| 6 (DI62) | Robot Not Operating -R | 6 (DO62) | Robot Eject Advance -R |
| 7 (DI63) | Eject Retreat Command -R | 7 (DO63) | Robot Auto -R |
| 8 (DI64) | Eject Advance Safety -R | 8 (DO64) | Mold Close End -R |
Euro 67 Robot Extension Points
| Ext DI | Signal | Ext DO | Signal |
|---|---|---|---|
| 1 (DI57) | Core Advance Safety #2 -R | 1 (DO57) | Robot Core Retreat -R |
| 2 (DI58) | Core Retreat Safety #2 -R | 2 (DO58) | Robot Core Advance #2 -R |
| 3 (DI59) | Mold Close Safety -R | 3 (DO59) | Robot Core Retreat #2 -R |
| 4 (DI60) | Robot E-Stop -R | 4 (DO60) | Mold Open End -R |
| 5 (DI61) | Mold Area Safety -R | 5 (DO61) | Robot Eject Retreat -R |
| 6 (DI62) | Robot Not Operating -R | 6 (DO62) | Robot Eject Advance -R |
| 7 (DI63) | Eject Retreat Command -R | 7 (DO63) | Robot Auto -R |
| 8 (DI64) | Eject Advance Safety -R | 8 (DO64) | Mold Close End -R |
Standard Configuration List
- Techmation iTECH5620 + 12 inch
- 2 groups of Blow Valves, No Nozzle Air Valve
- Core (Standard / Reserved): 1 group / 1 group (320); 2 groups / 0 groups (430)
Points marked with * are reserved when using a proportional valve.