Standard IOTechmation5620_320-430_M8II(Techmation)_Proportional-Valve_Standard_Euro12_Euro67

5620_320-430_M8II(Techmation)_Proportional-Valve_Standard_Euro12_Euro67

Source file: 5620_320-430_M8II(Techmation)_Proportional-Valve_Standard_Euro12_Euro67_20260501. Configuration: DI32 / DO32 / TC 1+6 / AI4 / AO4V2A / RDO3+3. Euro 12 / Euro 67 robot have different extension points, see respective tables below.

Main Board IO

Digital Input DI (32 points)

PointName
DI1Mechanical Safety Detection
DI2Safety Door 2
DI3Core A Advance End
DI4Core A Retreat End
DI5Core B Advance End
DI6Core B Retreat End
DI7Mold Close End
DI8Mold Adjust Advance End
DI9Mold Adjust Retreat End
DI10
DI11Injection Guard
DI12Eject Retreat End
DI13Robot -R
DI14Carriage Advance End
DI15Rear Safety Door Close End (Reverse Logic)
DI16Oil Filter Detection
DI17Recovery Speed
DI18Mold Adjust Photocell
DI19Detection Photocell
DI20Thread A Photocell
DI21Safety Door Close (Reverse Logic)
DI22Core C Advance End (Reserved)
DI23Core C Retreat End (Reserved)
DI24Lubrication Detection
DI25Hydraulic Oil Level Detection (430)
DI26
DI27
DI28
DI29
DI30Motor Phase Sequence Detection (430)
DI31External Control Pressure Insufficient (430)
DI32Cycle Start Button (430)

Digital Output DO (32 points)

PointName
DO1*Mold Close
DO2*Differential
DO3*Mold Open
DO4Injection
DO5Injection Retreat
DO6Recovery
DO7Carriage Advance
DO8Carriage Retreat
DO9Eject Advance
DO10Eject Retreat
DO11Core A Advance
DO12Core A Retreat
DO13Mold Adjust Advance
DO14Mold Adjust Retreat
DO15Core B Advance
DO16Core B Retreat
DO17Safety Door Close -R
DO18Recovery Back Pressure
DO19Blow 1
DO20Zero Back Pressure
DO21
DO22*Mold Open Slow Start (320) / Mold Open Fast (430)
DO23Alarm
DO24
DO25Mold Close Safety Valve
DO26Auto Light
DO27Manual Light
DO28Blow 2
DO29Core C Advance (Reserved)
DO30Core C Retreat (Reserved)
DO31Hopper Cooling (Reserved)
DO32Oil Temp Cooling (Reserved) / *Mold Close Low Pressure

Fixed Extension DO (49~54)

PointName
DO49Motor OFF
DO50Motor ON
DO51Y TO DELTA
DO52Heater ON
DO53Lubrication
DO54Robot -R

Analog AI / AO

PointName
AI1Injection
AI2Mold Open/Close
AI3Ejector
AI4
AO1Pump 1 Pressure
AO2Pump 1 Flow
P3±Proportional Back Pressure
P4±
AO5Proportional Valve
AO6Electric Recovery

Temperature TI / TO

PointNote
TIOILOil Temp
TI1
TI2
TI3
TI4
TI5
TI6
TO1
TO290-170 (incl.) Models, 4 zones
TO3218 Models, 5 zones
TO4268-430 (incl.) Models, 6 zones
TO5
TO6

Euro 12 Robot Extension Points

Ext DISignalExt DOSignal
1 (DI57)1 (DO57)
2 (DI58)2 (DO58)
3 (DI59)Mold Close Safety -R3 (DO59)
4 (DI60)Robot E-Stop -R4 (DO60)Mold Open End -R
5 (DI61)Mold Area Safety -R5 (DO61)Robot Eject Retreat -R
6 (DI62)Robot Not Operating -R6 (DO62)Robot Eject Advance -R
7 (DI63)Eject Retreat Command -R7 (DO63)Robot Auto -R
8 (DI64)Eject Advance Safety -R8 (DO64)Mold Close End -R

Euro 67 Robot Extension Points

Ext DISignalExt DOSignal
1 (DI57)Core Advance Safety #2 -R1 (DO57)Robot Core Retreat -R
2 (DI58)Core Retreat Safety #2 -R2 (DO58)Robot Core Advance #2 -R
3 (DI59)Mold Close Safety -R3 (DO59)Robot Core Retreat #2 -R
4 (DI60)Robot E-Stop -R4 (DO60)Mold Open End -R
5 (DI61)Mold Area Safety -R5 (DO61)Robot Eject Retreat -R
6 (DI62)Robot Not Operating -R6 (DO62)Robot Eject Advance -R
7 (DI63)Eject Retreat Command -R7 (DO63)Robot Auto -R
8 (DI64)Eject Advance Safety -R8 (DO64)Mold Close End -R

Standard Configuration List

  • Techmation iTECH5620 + 12 inch
  • 2 groups of Blow Valves, No Nozzle Air Valve
  • Core (Standard / Reserved): 1 group / 1 group (320); 2 groups / 0 groups (430)

Points marked with * are reserved when using a proportional valve.