ES750N Driver Overview

The ES750N series is Inovance’s dual-axis servo drive platform for hydraulic servo applications, supporting 11kW–55kW (T1/T2/T3 chassis). It can drive two permanent-magnet synchronous motors simultaneously (U1V1W1 + U2V2W2), has a built-in pressure-control mode, supports resolvers and 23-bit encoders, and supports EtherCAT and CAN.

Manual sections

SectionDescription
Electrical Installation & DesignMain-circuit wiring, terminal definitions, cable sizing, grounding, control circuit, encoder interface, communication interface
Quick Tuning GuidePower-on checks, F1-group motor settings, motor-parameter identification, A3 pressure-mode setup, PID tuning, holding-pressure stability
TroubleshootingFault reset methods, common symptoms, fault-code list (E002.0–E093.3)
Parameter ListFunction-code group index
Mixed-Motor Debug ParametersES680N (injection) + ES750N mixed-motor drive-commissioning parameter reference

Suggested reading path

  1. First-time installation — Read Electrical Installation & Design first to verify main-circuit, encoder, and communication wiring.
  2. First-time commissioning — Read the Quick Tuning Guide and follow the steps for parameter reset, motor identification, and pressure-mode setup.
  3. When alarms occur — Check Troubleshooting to locate the fault code and apply the recommended remedy.
  4. Mixed-motor commissioning — For the ES680N + ES750N mixed-motor setup, see Mixed-Motor Debug Parameters.

HMD high-speed-machine quick-tuning parameters

The following are key parameters for HMD high-speed injection-molding machines under typical configurations. Confirm the actual values for each machine type on-site.

CodeNameReference valueNotes
FP-01Parameter init1Restore factory settings
F0-01Control mode1 (FVC closed-loop vector)Set automatically in pressure mode
F0-02Command source1 (terminal) / 3 (communication)Set to 1 automatically in pressure mode
F0-17Acceleration time0Set to 0 automatically in pressure mode
F0-18Deceleration time0Set to 0 automatically in pressure mode
F1-00Motor type2 (synchronous motor)Set to 2 automatically in pressure mode
F1-01Rated powerPer nameplatekW
F1-02Rated voltage380V
F1-03Rated currentPer nameplateA
F1-04Rated frequencyPer nameplateHz
F1-05Rated speedPer nameplaterpm
F1-16Motor-parameter identification1 / 2 / 31 = static, 2 = dynamic, 3 = loaded static
F9-96Runaway alarm mode2Recommended for mixed-motor
F8-46Encoder multi-turn overflow mask1Recommended for mixed-motor
A3-00Pressure mode2 (analog input)Select per actual config
A5-08ECAT servo control mode1 (axis 002 only)Mixed-motor ECAT config